- Visión General
- Product Description
- Detailed Photos
- Specifications
- Other Model
- Customer Photo
Información Básica.
No. de Modelo.
DEFI 5S
Estilo
Sencillo
Impresión de la insignia
personalizado
Grupo
todos
Característica
Reutilizable
tipo de desfibrilador
sincronizado manualmente asincrónico
fuente de alimentación de ca
100v-240v 50hz/60hz
Paquete de Transporte
Wooden Carton
Especificación
Package Size: 54*45*37cm
Marca Comercial
Foinoe
Origen
China
Capacidad de Producción
5000pieces/Month
Descripción de Producto
Automatic External Defibrillator DEFI 5S
Advantages 2 Language to choose (by End user) 5 Levels of sound volume (by End user) Adult / Child mode Button Infra-red for data transmission (standard) Daily, Weekly and Monthly self-test Using the AED while in bag (dont need to open it) Extra pocket in bag for first Aid products IPX55 water and dust resistant Features * Three-step defibrillation process defibrillator * Selectable Energy for different age patients 50, 50, 75 Joule 150, 150, 200 Joule * Extensive voice and visual prompts for the operator * Changeable language manually * Biphasic energy output * Lock-out protection to prevent inadvertent defibrillation * Device has an internal memory(60 hours) * ECG signals and events can be transferred to the computer * Defi®5s pro AED is provided with carrying case,Battery,Pad,software for data transmission * It has long-life disposable LiMnO2 type battery (Battery life of at least 5 years) * AED Storage Software (Standard configration) Its used to assist upper supervisory system of Automatic External Defibrillator DEFI® The interface display status information recorded in the running of the AED, including type, event time, description, waves. Event type includes on event, self-test event, analyzing event, charging event, discharging event, CPR starting event, CPR stopping event. The event time displayed is when the event happened. Description shows the parameter information. "OHM" represents the detected impedance of the patient. Power parameter represents the voltage of the finished charging; "need to shock" represents that shock advised after analyzing "no need to shock" represents that no shock advised after analyzing. Waveform represents the link of the ECG waves . Waveform gain can be set as 5mm/mv,10mm/mv,20mm/mv; Waveform speed can be set as 12.5mm/s,25mm/s,50mm/s: Print ECG Click the "print" in ECG waveform display interface, then enter the setting interface of print. |
Send your message to us and click "Send" now